2.50
Hdl Handle:
http://hdl.handle.net/10755/152617
Type:
Presentation
Title:
Validation of the Children's Hospital of Iowa Infant Pain (CHIIP) Scale
Abstract:
Validation of the Children's Hospital of Iowa Infant Pain (CHIIP) Scale
Conference Sponsor:Sigma Theta Tau International
Conference Year:2005
Author:Kleiber, Charmaine, RN, PhD, FAAN
P.I. Institution Name:University of Iowa
Title:Associate Professor
Co-Authors:Lisa Bartruff, RN, BSN; Susan Berends, RN, MSN; Linda Crowley, RN, BSN; Janet Geyer, RN, MSN; Sara Gordon, RN, BSN; Stephanie Stewart, RN, MSN; Apawan Nookong, RN
Many infant pain scales lack clinical utility because of complex scoring or restrictions to gestational age groups. A psychometrically sound, clinically feasible pain scale is needed that is useful with infants of varying gestational ages. Building on existing research, the CHIIP (Children's Hospital of Iowa Infant Pain) scale was designed for clinical utility. Preliminary Work: Initial testing for reliability and validation of the CHIIP scale was performed. Seven infants (28 to 38 weeks adjusted gestation) were videotaped during painless or painful episodes. Twenty NICU nurses independently rated the videos. Reliability was estimated with Cronbach's alpha (r = .80) and the interclass correlation coefficient (r = .99). Construct validity was investigated by comparing change scores for infants in the NICU receiving pain medication. The clinical records of 20 infants were examined for pain scores prior to pain medication and one hour after pain medication. The average pain score decreased by 2 ¿÷ points (p Methods: The CHIIP Scale's ability to discriminate between pain in infants before and after pain medication is an indication of construct validity. Subjects are infants in the NICU who are receiving medication for pain. The infants are videotaped for one minute immediately prior to pain medication delivery and videotaped one hour after the medication. Twenty babies from each age group (< 28, 28 to 36, and ¦+ 37 weeks adjusted gestation) will be videotaped. The videotapes will be randomized and scored by two trained independent raters. Change scores (from pre pain medication to post pain medication) will be computed for each subject, and each age group will be reported separately. Based on the preliminary work, a sample of 15 per group is sufficient for a power of .9 with alpha set at .01.
Repository Posting Date:
26-Oct-2011
Date of Publication:
17-Oct-2011
Sponsors:
Sigma Theta Tau International

Full metadata record

DC FieldValue Language
dc.typePresentationen_GB
dc.titleValidation of the Children's Hospital of Iowa Infant Pain (CHIIP) Scaleen_GB
dc.identifier.urihttp://hdl.handle.net/10755/152617-
dc.description.abstract<table><tr><td colspan="2" class="item-title">Validation of the Children's Hospital of Iowa Infant Pain (CHIIP) Scale</td></tr><tr class="item-sponsor"><td class="label">Conference Sponsor:</td><td class="value">Sigma Theta Tau International</td></tr><tr class="item-year"><td class="label">Conference Year:</td><td class="value">2005</td></tr><tr class="item-author"><td class="label">Author:</td><td class="value">Kleiber, Charmaine, RN, PhD, FAAN</td></tr><tr class="item-institute"><td class="label">P.I. Institution Name:</td><td class="value">University of Iowa</td></tr><tr class="item-author-title"><td class="label">Title:</td><td class="value">Associate Professor</td></tr><tr class="item-email"><td class="label">Email:</td><td class="value">charmaine-kleiber@uiowa.edu</td></tr><tr class="item-co-authors"><td class="label">Co-Authors:</td><td class="value">Lisa Bartruff, RN, BSN; Susan Berends, RN, MSN; Linda Crowley, RN, BSN; Janet Geyer, RN, MSN; Sara Gordon, RN, BSN; Stephanie Stewart, RN, MSN; Apawan Nookong, RN</td></tr><tr><td colspan="2" class="item-abstract">Many infant pain scales lack clinical utility because of complex scoring or restrictions to gestational age groups. A psychometrically sound, clinically feasible pain scale is needed that is useful with infants of varying gestational ages. Building on existing research, the CHIIP (Children's Hospital of Iowa Infant Pain) scale was designed for clinical utility. Preliminary Work: Initial testing for reliability and validation of the CHIIP scale was performed. Seven infants (28 to 38 weeks adjusted gestation) were videotaped during painless or painful episodes. Twenty NICU nurses independently rated the videos. Reliability was estimated with Cronbach's alpha (r = .80) and the interclass correlation coefficient (r = .99). Construct validity was investigated by comparing change scores for infants in the NICU receiving pain medication. The clinical records of 20 infants were examined for pain scores prior to pain medication and one hour after pain medication. The average pain score decreased by 2 &iquest;&divide; points (p Methods: The CHIIP Scale's ability to discriminate between pain in infants before and after pain medication is an indication of construct validity. Subjects are infants in the NICU who are receiving medication for pain. The infants are videotaped for one minute immediately prior to pain medication delivery and videotaped one hour after the medication. Twenty babies from each age group (&lt; 28, 28 to 36, and &brvbar;+ 37 weeks adjusted gestation) will be videotaped. The videotapes will be randomized and scored by two trained independent raters. Change scores (from pre pain medication to post pain medication) will be computed for each subject, and each age group will be reported separately. Based on the preliminary work, a sample of 15 per group is sufficient for a power of .9 with alpha set at .01.</td></tr></table>en_GB
dc.date.available2011-10-26T11:43:03Z-
dc.date.issued2011-10-17en_GB
dc.date.accessioned2011-10-26T11:43:03Z-
dc.description.sponsorshipSigma Theta Tau Internationalen_GB
All Items in this repository are protected by copyright, with all rights reserved, unless otherwise indicated.