Development of the Irrational Belief Test for Nurses (IBTN): Examination of Reliability and Validity

2.50
Hdl Handle:
http://hdl.handle.net/10755/155842
Type:
Presentation
Title:
Development of the Irrational Belief Test for Nurses (IBTN): Examination of Reliability and Validity
Abstract:
Development of the Irrational Belief Test for Nurses (IBTN): Examination of Reliability and Validity
Conference Sponsor:Sigma Theta Tau International
Conference Year:2010
Author:Ohue, Takashi, RN, MA
P.I. Institution Name:Hiroshima University
Title:Graduate student
Co-Authors:Michiko Moriyama, RN, PhD; Takashi Nakaya, PhD
21st INRC [Evidence-Based Practice Presentation] Purpose: The purpose of this study is to develop irrational belief test for nurses, and to examine reliability and validity. Method: In study 1, The Irrational belief test for nurses was developed based JIBT-20 (Mori et al, 1994) of previous studies. And for the nurse (N=96, 5 male, 91 female), carried out preliminary investigation, created the provisional version of the Irrational belief test for nurses, and examined factor structure and internal consistency. In study 2, for the nurse (N=541, 21 males, 520 females) examined validity based on JIBT-20 (Japanese Irrational Belief Test), MBI (Maslach Burnout Inventory), ATQ-R Japanese version (Automatic Thoughts Questionnaire-Revised), and for the nurse (N=91, 3 male, 88 female) examined a test-retest reliability four weeks afterward before long. Result: As a result of the explanatory factor analysis by a maximum likelihood estimation and promax rotation, 28-item 7 factors were extracted and was named a "patient belief," "self-expectation," "avoidance," "self-inhibition," "ethical blame," "helplessness," and "dependence." Moreover, as a result of conducting confirmation factor analysis, the hypothetical model obtained by explanatory factor analysis fitted (GFI=0.89,AGFI=0.86). About the reliability of the measure, a Cronbach's alpha coefficient is 0.68-0.82, and a test-retest reliability is 0.64 and reliability was affirmed. About construct validity was checked correlation with JIBT-20, and about criterion validity was checked the correlation with MBI and ATQ-R Japanese-translation version. Conclusion: It was suggested that reliability and validity are verified and the irrational belief test for nurses is a useful measure. Ethical considerations: The research protocol was approved by the Hiroshima University Ethics Committee. With regards to ethical considerations, protection of anonymity and privacy were explained and consent from was received from each subjects.
Repository Posting Date:
26-Oct-2011
Date of Publication:
17-Oct-2011
Sponsors:
Sigma Theta Tau International

Full metadata record

DC FieldValue Language
dc.typePresentationen_GB
dc.titleDevelopment of the Irrational Belief Test for Nurses (IBTN): Examination of Reliability and Validityen_GB
dc.identifier.urihttp://hdl.handle.net/10755/155842-
dc.description.abstract<table><tr><td colspan="2" class="item-title">Development of the Irrational Belief Test for Nurses (IBTN): Examination of Reliability and Validity</td></tr><tr class="item-sponsor"><td class="label">Conference Sponsor:</td><td class="value">Sigma Theta Tau International</td></tr><tr class="item-year"><td class="label">Conference Year:</td><td class="value">2010</td></tr><tr class="item-author"><td class="label">Author:</td><td class="value">Ohue, Takashi, RN, MA</td></tr><tr class="item-institute"><td class="label">P.I. Institution Name:</td><td class="value">Hiroshima University</td></tr><tr class="item-author-title"><td class="label">Title:</td><td class="value">Graduate student</td></tr><tr class="item-email"><td class="label">Email:</td><td class="value">takashimoon2001@yahoo.co.jp</td></tr><tr class="item-co-authors"><td class="label">Co-Authors:</td><td class="value">Michiko Moriyama, RN, PhD; Takashi Nakaya, PhD</td></tr><tr><td colspan="2" class="item-abstract">21st INRC [Evidence-Based Practice Presentation] Purpose: The purpose of this study is to develop irrational belief test for nurses, and to examine reliability and validity. Method: In study 1, The Irrational belief test for nurses was developed based JIBT-20 (Mori et al, 1994) of previous studies. And for the nurse (N=96, 5 male, 91 female), carried out preliminary investigation, created the provisional version of the Irrational belief test for nurses, and examined factor structure and internal consistency. In study 2, for the nurse (N=541, 21 males, 520 females) examined validity based on JIBT-20 (Japanese Irrational Belief Test), MBI (Maslach Burnout Inventory), ATQ-R Japanese version (Automatic Thoughts Questionnaire-Revised), and for the nurse (N=91, 3 male, 88 female) examined a test-retest reliability four weeks afterward before long. Result: As a result of the explanatory factor analysis by a maximum likelihood estimation and promax rotation, 28-item 7 factors were extracted and was named a &quot;patient belief,&quot; &quot;self-expectation,&quot; &quot;avoidance,&quot; &quot;self-inhibition,&quot; &quot;ethical blame,&quot; &quot;helplessness,&quot; and &quot;dependence.&quot; Moreover, as a result of conducting confirmation factor analysis, the hypothetical model obtained by explanatory factor analysis fitted (GFI=0.89,AGFI=0.86). About the reliability of the measure, a Cronbach's alpha coefficient is 0.68-0.82, and a test-retest reliability is 0.64 and reliability was affirmed. About construct validity was checked correlation with JIBT-20, and about criterion validity was checked the correlation with MBI and ATQ-R Japanese-translation version. Conclusion: It was suggested that reliability and validity are verified and the irrational belief test for nurses is a useful measure. Ethical considerations: The research protocol was approved by the Hiroshima University Ethics Committee. With regards to ethical considerations, protection of anonymity and privacy were explained and consent from was received from each subjects.</td></tr></table>en_GB
dc.date.available2011-10-26T14:13:37Z-
dc.date.issued2011-10-17en_GB
dc.date.accessioned2011-10-26T14:13:37Z-
dc.description.sponsorshipSigma Theta Tau Internationalen_GB
All Items in this repository are protected by copyright, with all rights reserved, unless otherwise indicated.