ABCDE Bundle Adherence: The Influence of Access to ABCDE-Enhancing Supplies and Equipment

2.50
Hdl Handle:
http://hdl.handle.net/10755/622141
Category:
Full-text
Format:
Text-based Document
Type:
Presentation
Level of Evidence:
N/A
Research Approach:
N/A
Title:
ABCDE Bundle Adherence: The Influence of Access to ABCDE-Enhancing Supplies and Equipment
Other Titles:
Interprofessional Collaboration Enhancing Clinical Outcomes
Author(s):
Boehm, Leanne M.
Lead Author STTI Affiliation:
Iota
Author Details:
Leanne M. Boehm, PhD, RN, ACNS-BC, Professional Experience: 13 years of critical care nursing 8 years of research nurse/project manager experience 2 years of quality improvement and implementation science advanced training 8 years of presentation/teaching experience Author Summary: Dr. Boehm is a postdoctoral fellow with Vanderbilt University School of Nursing. Her research interests include the physical, mental, and cognitive sequelae associated with critical illness; quality improvement and implementation science; and factors influencing interprofessional efforts in the acute care setting. Her dissertation study examined the organizational domains influencing interprofessional protocol implementation in intensive care, focusing specifically on implementation of the ABCDE bundle. She is part of the ICU Delirium and Cognitive Impairment Study Group.
Abstract:

Purpose: The ABCDE interprofessional bundle (Awakening and Breathing Coordination, Delirium monitoring and management, and Early mobility) is an evidence-based approach to organizing Intensive Care Unit (ICU) people, processes, and technology to improve collaboration among disciplines and standardize critical care practices. Implementation of the ABCDE bundle is associated with improvements in delirium prevalence (62.3% pre-implementation vs 48.7% post-implementation, p =0.02), ventilator-free days (21 pre-implementation vs 24 post-implementation, p =0.04), and hospital mortality (20% pre-implementation vs 11% post-implementation, p =0.04). Despite this evidence, bundle adoption is limited. The perceived workload burden of ABCDE bundle execution has been inversely associated with likelihood of bundle adherence (OR=0.47, CI=0.28-0.79, p=0.004). Furthermore, limited access to supplies and equipment for ABCDE bundle execution is associated with increased difficulty performing the bundle (rs=0.37, p

Methods: This is a secondary analysis of data from a pilot study investigating organizational factors influencing ABCDE bundle implementation. The Conceptual Framework for Interprofessional Bundle Implementation guided the study. Physical environment data were collected from participating medical and surgical ICUs (n=10) in six academic medical centers. The principal investigator personally visited each site between April 2014 and August 2015, during which time available ABCDE-enhancing supplies and equipment were logged. Daily execution of the ABCDE bundle was at the discretion of the ICU team and guided by a standardized protocol. Adherence was tracked daily via the ABCDE bundle checklist. ABCDE bundle adherence is defined as all five components being completed on a ventilator day (i.e., Awakening trial [SAT], Breathing trial [SBT], Coordination [SAT precedes SBT], Delirium assessment, Early mobility). ABCDE bundle adherence was aggregated at the unit level.

Results: Variation in ABCDE bundle adherence on ventilator days was noted to range between 38% and 85% across units. ABCDE bundle adherence was lesser in surgical ICUs compared to medical ICUs, but this did not reach statistical significance (63% vs. 75%, z=1.89, p=0.059). Upon evaluation of individual bundle components, Coordination (89%) and Early mobility (86%) had the least adherence for mechanically ventilated patients. Unit ABCDE-enhancing supply/equipment comparison demonstrated a range of 3-10 accessible items across units. The highest performing unit (adherence=85%) had access to two ABCDE-enhancing items while the lowest performing unit (adherence=38%) had access to seven ABCDE-enhancing items. The most frequently reported ABCDE-enhancing items (>=80%) include walkers (n=9) and overhead lifts (n=7). The least commonly reported ABCDE-enhancing items (

Conclusion: The ABCDE bundle is recommended practice for critical care, but utilization is low and implementation varies. In this study, the number of ABCDE-enhancing supplies/equipment procured by the ICU is not noted to be consistent with greater adherence to the ABCDE bundle. In fact, there were more than twice the number of ABCDE-enhancing items in the lowest (n=7) performing unit compared to the highest performing unit (n=2). These data suggest that environmental factors contributing to the workload burden of ABCDE bundle execution may not be so much related to the presence or absence of ABCDE-enhancing supplies/equipment, but more so to unit architecture (e.g., configuration, number of corners) or distances to supplies/equipment. However, unit milieu (e.g., teamwork, coordination across disciplines) and policy and protocol factors (e.g., protocol complexity, role clarity) must also be more closely explored.

Keywords:
bundle; intensive care unit; interprofessional
Repository Posting Date:
25-Jul-2017
Date of Publication:
25-Jul-2017
Other Identifiers:
INRC17L11
Conference Date:
2017
Conference Name:
28th International Nursing Research Congress
Conference Host:
Sigma Theta Tau International
Conference Location:
Dublin, Ireland
Description:
Event Theme: Influencing Global Health Through the Advancement of Nursing Scholarship

Full metadata record

DC FieldValue Language
dc.language.isoen_USen
dc.type.categoryFull-texten
dc.formatText-based Documenten
dc.typePresentationen
dc.evidence.levelN/Aen
dc.research.approachN/Aen
dc.titleABCDE Bundle Adherence: The Influence of Access to ABCDE-Enhancing Supplies and Equipmenten_US
dc.title.alternativeInterprofessional Collaboration Enhancing Clinical Outcomesen
dc.contributor.authorBoehm, Leanne M.en
dc.contributor.departmentIotaen
dc.author.detailsLeanne M. Boehm, PhD, RN, ACNS-BC, Professional Experience: 13 years of critical care nursing 8 years of research nurse/project manager experience 2 years of quality improvement and implementation science advanced training 8 years of presentation/teaching experience Author Summary: Dr. Boehm is a postdoctoral fellow with Vanderbilt University School of Nursing. Her research interests include the physical, mental, and cognitive sequelae associated with critical illness; quality improvement and implementation science; and factors influencing interprofessional efforts in the acute care setting. Her dissertation study examined the organizational domains influencing interprofessional protocol implementation in intensive care, focusing specifically on implementation of the ABCDE bundle. She is part of the ICU Delirium and Cognitive Impairment Study Group.en
dc.identifier.urihttp://hdl.handle.net/10755/622141-
dc.description.abstract<p><strong>Purpose: </strong><span>The ABCDE interprofessional bundle (</span><strong>A</strong><span>wakening and </span><strong>B</strong><span>reathing </span><strong>C</strong><span>oordination, </span><strong>D</strong><span>elirium monitoring and management, and </span><strong>E</strong><span>arly mobility) is an evidence-based approach to organizing Intensive Care Unit (ICU) people, processes, and technology to improve collaboration among disciplines and standardize critical care practices. Implementation of the ABCDE bundle is associated with improvements in delirium prevalence (62.3% pre-implementation vs 48.7% post-implementation, </span><em>p</em><span> =0.02), ventilator-free days (21 pre-implementation vs 24 post-implementation, </span><em>p</em><span> =0.04), and hospital mortality (20% pre-implementation vs 11% post-implementation, </span><em>p</em><span> =0.04). Despite this evidence, bundle adoption is limited. The perceived workload burden of ABCDE bundle execution has been inversely associated with likelihood of bundle adherence (OR=0.47, CI=0.28-0.79, </span><em>p</em><span>=0.004). Furthermore, limited access to supplies and equipment for ABCDE bundle execution is associated with increased difficulty performing the bundle (</span><em>r<sub>s</sub></em><span>=0.37, </span><em>p</em></p> <p><strong>Methods: </strong>This is a secondary analysis of data from a pilot study investigating organizational factors influencing ABCDE bundle implementation. The Conceptual Framework for Interprofessional Bundle Implementation guided the study. Physical environment data were collected from participating medical and surgical ICUs (n=10) in six academic medical centers. The principal investigator personally visited each site between April 2014 and August 2015, during which time available ABCDE-enhancing supplies and equipment were logged. Daily execution of the ABCDE bundle was at the discretion of the ICU team and guided by a standardized protocol. Adherence was tracked daily via the ABCDE bundle checklist. ABCDE bundle adherence is defined as all five components being completed on a ventilator day (i.e., <strong>A</strong>wakening trial [SAT], <strong>B</strong>reathing trial [SBT], <strong>C</strong>oordination [SAT precedes SBT], <strong>D</strong>elirium assessment, <strong>E</strong>arly mobility). ABCDE bundle adherence was aggregated at the unit level.</p> <p><strong>Results: </strong>Variation in ABCDE bundle adherence on ventilator days was noted to range between 38% and 85% across units. ABCDE bundle adherence was lesser in surgical ICUs compared to medical ICUs, but this did not reach statistical significance (63% vs. 75%, <em>z</em>=1.89, <em>p</em>=0.059). Upon evaluation of individual bundle components, <strong>C</strong>oordination (89%) and <strong>E</strong>arly mobility (86%) had the least adherence for mechanically ventilated patients. Unit ABCDE-enhancing supply/equipment comparison demonstrated a range of 3-10 accessible items across units. The highest performing unit (adherence=85%) had access to two ABCDE-enhancing items while the lowest performing unit (adherence=38%) had access to seven ABCDE-enhancing items. The most frequently reported ABCDE-enhancing items (>=80%) include walkers (n=9) and overhead lifts (n=7). The least commonly reported ABCDE-enhancing items (</p> <p><strong>Conclusion: </strong>The ABCDE bundle is recommended practice for critical care, but utilization is low and implementation varies. In this study, the number of ABCDE-enhancing supplies/equipment procured by the ICU is not noted to be consistent with greater adherence to the ABCDE bundle. In fact, there were more than twice the number of ABCDE-enhancing items in the lowest (n=7) performing unit compared to the highest performing unit (n=2). These data suggest that environmental factors contributing to the workload burden of ABCDE bundle execution may not be so much related to the presence or absence of ABCDE-enhancing supplies/equipment, but more so to unit architecture (e.g., configuration, number of corners) or distances to supplies/equipment. However, unit milieu (e.g., teamwork, coordination across disciplines) and policy and protocol factors (e.g., protocol complexity, role clarity) must also be more closely explored.</p>en
dc.subjectbundleen
dc.subjectintensive care uniten
dc.subjectinterprofessionalen
dc.date.available2017-07-25T18:37:13Z-
dc.date.issued2017-07-25-
dc.date.accessioned2017-07-25T18:37:13Z-
dc.conference.date2017en
dc.conference.name28th International Nursing Research Congressen
dc.conference.hostSigma Theta Tau Internationalen
dc.conference.locationDublin, Irelanden
dc.descriptionEvent Theme: Influencing Global Health Through the Advancement of Nursing Scholarshipen
All Items in this repository are protected by copyright, with all rights reserved, unless otherwise indicated.